§192.459 External corrosion control: Examination of buried pipeline when exposed

Current as of Oct 29, 2026Last amended Dec 19, 2016Official text on eCFR ↗

Whenever an operator has knowledge that any portion of a buried pipeline is exposed, the exposed portion must be examined for evidence of external corrosion if the pipe is bare, or if the coating is deteriorated. If external corrosion requiring remedial action under §§ 192.483 through 192.489 is found, the operator shall investigate circumferentially and longitudinally beyond the exposed portion (by visual examination, indirect method, or both) to determine whether additional corrosion requiring remedial action exists in the vicinity of the exposed portion.

Source: Amdt. 192-87, 64 FR 56981, Oct. 22, 1999

Compiled from the Electronic Code of Federal Regulations (eCFR), an editorial compilation and not an official legal edition of the CFR. The official text is the Federal Register and the annual CFR edition. §192.459 on eCFR.

Sections that cite this one

  • §192.917 How does an operator identify potential threats to pipeline integrity and use the threat identification in its integrity program?