§192.113 Longitudinal joint factor (E) for steel pipe

Current as of Oct 29, 2026Last amended Mar 16, 2026Official text on eCFR ↗

(a) The longitudinal joint factor to be used in the design formula in § 192.105 is determined in accordance with the table 1 to this paragraph (a):

Table 1 to Paragraph (a)

SpecificationPipe classLongitudinal joint factor (E)
ASTM A53/A53M (incorporated by reference, see § 192.7)Seamless1.00
Electric resistance welded1.00
Furnace butt welded.60
ASTM A106/A106M (incorporated by reference, see § 192.7)Seamless1.00
ASTM A333/A333M (incorporated by reference, see § 192.7)Seamless1.00
Electric resistance welded1.00
ASTM A381 (incorporated by reference, see § 192.7)Double submerged arc welded1.00
ASTM A671/A671M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00
ASTM A672/A672M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00
ASTM A691/A691M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00
API Spec 5L (incorporated by reference, see § 192.7)Seamless1.00
Electric resistance welded1.00
Electric flash welded1.00
Submerged arc welded1.00
Furnace butt welded.60
OtherPipe over 4 inches (102 millimeters).80
OtherPipe 4 inches (102 millimeters) or less.60

(b) If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for “Other.”

Source: Amdt. 192-135, 89 FR 33280, Apr. 29, 2024, as amended by Amdt. 192-156, 90 FR 40763, Aug. 21, 2025

Compiled from the Electronic Code of Federal Regulations (eCFR), an editorial compilation and not an official legal edition of the CFR. The official text is the Federal Register and the annual CFR edition. §192.113 on eCFR.

Sections that cite this one

  • §192.7 What documents are incorporated by reference partly or wholly in this part?
  • §192.105 Design formula for steel pipe.
  • §192.917 How does an operator identify potential threats to pipeline integrity and use the threat identification in its integrity program?