§192.18 How to notify PHMSA

Current as of Oct 29, 2026Last amended Jan 10, 2026Official text on eCFR ↗

(a) An operator must provide any notification required by this part by—

(1) Sending the notification by electronic mail to InformationResourcesManager@dot.gov; or

(2) Sending the notification by mail to ATTN: Information Resources Manager, Office of Pipeline Safety, Pipeline and Hazardous Materials Safety Administration, PHF-30, 1200 New Jersey Avenue SE, Washington, DC 20590.

(b) An operator must also notify the appropriate State or local pipeline safety authority when an applicable pipeline segment is located in a State where OPS has an interstate agent agreement, or an intrastate applicable pipeline segment is regulated by that State.

(c) Unless otherwise specified, if an operator submits, pursuant to § 192.8, § 192.9, § 192.13, § 192.179, § 192.319, § 192.461, § 192.506, § 192.607, § 192.619, § 192.624, § 192.632, § 192.634, § 192.636, § 192.710, § 192.712, § 192.714, § 192.745, § 192.917, § 192.921, § 192.927, § 192.933, or § 192.937, a notification for use of a different integrity assessment method, analytical method, compliance period, sampling approach, pipeline material, or technique (e.g., “other technology” or “alternative equivalent technology”) than otherwise prescribed in those sections, that notification must be submitted to PHMSA for review at least 90 days in advance of using the other method, approach, compliance timeline, or technique. An operator may proceed to use the other method, approach, compliance timeline, or technique 91 days after submitting the notification unless it receives a letter from the Associate Administrator for Pipeline Safety informing the operator that PHMSA objects to the proposal or that PHMSA requires additional time and/or more information to conduct its review.

Source: Amdt. 192-125, 84 FR 52244, Oct. 1, 2019, as amended by Amdt. 192-129, 86 FR 63298, Nov. 15, 2021; Amdt. 192-130, 87 FR 20982, Apr. 8, 2022; Amdt. 192-132, 87 FR 52268, Aug. 24, 2022; Amdt. 192-156, 90 FR 40762, Aug. 21, 2025

Compiled from the Electronic Code of Federal Regulations (eCFR), an editorial compilation and not an official legal edition of the CFR. The official text is the Federal Register and the annual CFR edition. §192.18 on eCFR.

Sections that cite this one

  • §192.8 How are onshore gathering pipelines and regulated onshore gathering pipelines determined?
  • §192.9 What requirements apply to gathering pipelines?
  • §192.13 What general requirements apply to pipelines regulated under this part?
  • §192.153 Components fabricated by welding.
  • §192.179 Transmission line valves.
  • §192.319 Installation of pipe in a ditch.
  • §192.461 External corrosion control: Protective coating.
  • §192.506 Transmission lines: Spike hydrostatic pressure test.
  • §192.607 Verification of Pipeline Material Properties and Attributes: Onshore steel transmission pipelines.
  • §192.611 Change in class location: Confirmation or revision of maximum allowable operating pressure.
  • §192.619 Maximum allowable operating pressure: Steel or plastic pipelines.
  • §192.624 Maximum allowable operating pressure reconfirmation: Onshore steel transmission pipelines.
  • §192.632 Engineering Critical Assessment for Maximum Allowable Operating Pressure Reconfirmation: Onshore steel transmission pipelines.
  • §192.634 Transmission lines: Onshore valve shut-off for rupture mitigation.
  • §192.636 Transmission lines: Response to a rupture; capabilities of rupture-mitigation valves (RMVs) or alternative equivalent technologies.
  • §192.710 Transmission lines: Assessments outside of high consequence areas.
  • §192.712 Analysis of predicted failure pressure and critical strain level.
  • §192.714 Transmission lines: Repair criteria for onshore transmission pipelines.
  • §192.745 Valve maintenance: Transmission lines.
  • §192.805 Qualification program.
  • §192.909 How can an operator change its integrity management program?
  • §192.917 How does an operator identify potential threats to pipeline integrity and use the threat identification in its integrity program?
  • §192.921 How is the baseline assessment to be conducted?
  • §192.927 What are the requirements for using Internal Corrosion Direct Assessment (ICDA)?
  • §192.933 What actions must be taken to address integrity issues?
  • §192.937 What is a continual process of evaluation and assessment to maintain a pipeline's integrity?
  • §192.939 What are the required reassessment intervals?